lzzbj6/9-10-c1/2-10kv-post-type-reinforced-cast-resin-current-transformer-with-protective-class, lzzbj6/9-10-c1/2-10kv-post-type-reinforced-cast-resin-current-transformer-with-protective-class, /current-transformer-series-10-24-kv
So'rov
lzzbj6/9-10-c1/2-10kv-post-type-reinforced-cast-resin-current-transformer-with-protective-class, lzzbj6/9-10-c1/2-10kv-post-type-reinforced-cast-resin-current-transformer-with-protective-class, 
So'rov

LZZBJ(6/9)-10 C(1/2) 10 kV ustun shaklidagi kuchaytirilgan qoplamali rezinaviy tok transformatori, himoya sinfi bilan

Nominal birinchi darajali tok 5-3000 A; aniqlik 0.2S/10P10, 0.5S/10P10, 0.2/10P10, 0.5/10P10, 0.2S/10P15; chiqish quvvati 10-30 VA; 1 s issiqlik 0.75-80 kA

So'rov yuborish
  • Umumiy ko'rinish

Umumiy ko'rinish

10 kV ustun turidagi tok Transformator Oilaviy

LZZBJ(6/9)-10 C(1/2) 10 kV liq qo‘yilgan rezinadan yasalgan, mustahkamlangan ustun turidagi tok transformatori, himoya sinfiga ega bo‘lgan, o‘rtacha kuchlanishli o‘lchash va himoya vazifalarini bajaradigan, mustahkamlangan, liq qo‘yilgan izolyatsiyali o‘lchov transformatorlarining bir oilasidir. Ushbu oilaga LZZBJ6-10 C, LZZBJ9-10 C1 va LZZBJ9-10 C2 konfiguratsiyalari kiradi. Har bir konfiguratsiya dizayn raqami va tuzilish kodi bilan aniqlanadi; shu sababli, sotib olishdan oldin tanlangan model, tok nisbati, chulg‘am joylashuvi, aniqlik kombinatsiyasi va yuklamani tasdiqlash kerak. Ushbu sahifa barcha variantlar uchun universal qiymat sifatida emas, balki tanlovga yordam berish uchun taqdim etilgan oila ma'lumotlarini beradi.

Oilaning konfiguratsiyasi va texnik doirasi

Konfiguratsiya Ta'minlangan ma'lumotlardagi birinchi darajali tok doirasi Ikkinchi darajali chulg‘am / aniqlik doirasi Ikkinchi darajali chiqish doirasi
LZZBJ9-10 C1 23 ta qadamda 5 dan 3000 A gacha Ikki chulg'am; 0.2S/10P10, 0.5S/10P10, 0.2/10P10 yoki 0.5/10P10 10 / 10 / 15 VA
LZZBJ6-10 C 23 ta qadamda 5 dan 3000 A gacha Ikki chulg'am; C1 uchun keltirilgan bir xil kombinatsiyalar 10 / 10 / 15 VA
LZZBJ9-10 C2 5–150, 200, 300–800, 1000–1500 va 2000–3150 A Ikki yoki uch chulg'amlı versiyalar; kombinatsiyalarga 10P15 variantlari ham kiradi konfiguratsiyaga qarab 10 dan 30 VA gacha

Taqdim etilgan ma'lumotlar oila uchun 10 kV nominal kuchlanishni ko'rsatadi. C1 va LZZBJ6 konfiguratsiyalari uchun keltirilgan bir soniya davomida termik tok qiymatlari past tomonda 0,75 kA dan, yuqori tomonda 2000–3000 A da 80 kA gacha o'zgaradi; keltirilgan dinamik tok qiymatlari esa 1,8 kA dan 160 kA gacha o'zgaradi. C2 ma'lumotlari tok diapazonlari va chulg'am bloklari bo'yicha tartiblangan. Ushbu raqamlar tanlangan nisbat va tasdiqlangan chizmaga mos kelishi kerak; ular faraz qilish orqali boshqa variantga qo'llanilmasin.

Loyihada ahamiyatli tanlash xususiyatlari

  • Hisoblash va himoya kombinatsiyalari: C1 va LZZBJ6 variantlari 0,2S/10P10 va 0,5S/10P10 kabi kombinatsiyalarni keltiradi. C2 variantlari 10P15 ni o'z ichiga olgan kombinatsiyalarni qo'shadi va ikkita yoki uchta chulg'am shaklida yetkazib berilishi mumkin.
  • Diapazonga bog'liq ishlash: Birinchi tok diapazonlari va qisqa tutashuvga chidash ko'rsatkichlari tanlangan konfiguratsiyaga qarab o'zgaradi. To'g'ri so'rovda faqat oila belgilanishidan foydalanish o'rniga, nominal birinchi tok va talab qilinadigan ikkinchi chiqish ko'rsatkichi ko'rsatilishi kerak.
  • Aniq terminal referenslari: Asosiy terminal-lar P1 va P2 deb belgilangan. Yetkazilgan C2 chizmasida ikkinchi darajali terminal-lar 1S1, 1S2, 2S1 va 2S2 ko'rsatilgan; buyurtma qilingan aniq model uchun terminal belgilari-ni tekshiring.
  • O'rnatish varianti: Ushbu oila asos-plita orqali o'rnatiladi. Manba materialida ba'zi konfiguratsiyalar uchun 4-M12 yoki 8-M12 tartiblar keltirilgan, LZZBJ6-10 C esa to'rtta 12 × 25 mm li slotlar bilan ko'rsatilgan.
  • Konfiguratsiyaga asoslangan sotib olish: Bir xil mahsulot oilasi nomi turli dizayn raqamlari, tuzilma kodlari va chulg'am variantlarini qamrab oladi. Moslikni ta'minlashning eng xavfsiz usuli — texnik jadvaldan foydalanish.

O'lchamlar va o'rnatish rejasi

Taqdim etilgan chizmalar turli mexanik o'lchamlarni ko'rsatadi. LZZBJ9-10 C1 270 mm yuqori kenglik, 222 mm balandlik va 155 mm yon ko'rinishdagi kenglik bilan, shuningdek, 275 yoki 310 mm asos uzunliklari bilan ko'rsatilgan. LZZBJ6-10 C 270 mm yuqori kenglik, 225 mm balandlik va 310 mm asos kengligi bilan ko'rsatilgan. LZZBJ9-10 C2 295 mm yuqori kenglik, 236±1 mm balandlik va 180 mm yon ko'rinishdagi kenglik bilan ko'rsatilgan. Bu chizmadan olingan referent qiymatlar; yakuniy panel joylashuvini amalga oshirishdan oldin mos chizma versiyasini va tanlangan tok diapazonini tasdiqlang.

lzzbj6-9-10-c1.2-dimensions-02.webp

Qo'llanilish sohalari va muhandislik foydalanishi

LZZBJ(6/9)-10 C(1/2) 10 kV li post turidagi mustahkamlangan qo‘yilma rezinaviy o‘tkazgich transformatori himoya klassi bilan birga tokni o‘lchash va himoya vazifalarini bajarish uchun 10 kV taqsimot uskunalari uchun mos keladi. Oddiy qo‘llanilish sohalari: o‘rta kuchlanishli elektr tarmog‘i uskunalari, himoya panellari, o‘lchov bo‘limlari va asosga o‘rnatiladigan post turidagi transformatorlardan foydalanadigan kubiklar. Har qanday variantning mosligi tizim kuchlanishiga, o‘tkazgichlar joylashishiga, izolyatsiya moslamasiga, ikkinchi darajali zanjir loyihasiga va loyiha himoya falsafasiga bog‘liq.

O‘lchov va himoya vazifalari uchun loyiha hujjatlarida qo‘llaniladigan aniqlik sinfi, yuk, rele talablari va g‘ildiraklar tartibini ko‘rsating. Keltirilgan ikkita g‘ildirakli va uchta g‘ildirakli tartiblarni haqiqiy sxema bilan solishtiring.

Bir yoy chiqishi tadqiqoti bu joriy transformator uchun mahsulot spetsifikatsiyasi emas, lekin uning tizim darajasidagi topilmalari uskunalar tanlovi atrofida himoya muhandisligi tekshiruvisini ta'minlaydi. Shunday qilib, trafikator sarimligi temperaturasi korsatgich boshqa nazorat maqsadlariga xizmat qiladi va joriy transformatorning ikkinchi aylanish zanjiri bilan chalkashib ketmasligi kerak. Bu funksiyalarni ajratib turish materiallar ro'yxati va texnik so'rovning aniqrog'i bo'lishiga yordam beradi.

Texnik tekshirish chek-ro'yxati

Sotib olish buyurtmasini berishdan oldin tanlangan model, asosiy va ikkinchi oqimlarning reyting qiymatlari, loyiha uchun mos keladigan holatlarda chastota, o'lchov va himoya sinfi kombinatsiyasi, reyting yuklamasi, ikkinchi aylanish chulg'amalarining soni, terminal talablari, o'rnatish chizmasi va miqdor keltirilishi kerak. O'rnatish uchun C, C1 yoki C2 tuzilish kodi talab qilinishini tasdiqlang. Agar loyihada maxsus izolyatsiya, masofa, rele moslashuvi yoki panel maydoni talablari bo'lsa, ularni so'rovda ko'rsating, shunda etkazib beruvchi tanlangan dastur ma'lumotlarini mo'ljallangan qo'llanilishga mosligini tekshirishi mumkin.

Tekshiring U nima maqbul
Model va tuzilma kodi LZZBJ6-10 C, LZZBJ9-10 C1 va C2 konfiguratsiyalarini ajratadi.
Birinchi oqim darajasi Qo'llaniladigan ma'lumotlar qatori va chidamlilik qiymatlarini belgilaydi.
Aniqlik / himoya kombinatsiyasi Ikkinchi darajali chiqishlarni o'lchash va rele funksiyalari bilan moslashtiradi.
Chulg'am soni Ikki yoki uchta mustaqil ikkinchi darajali funksiya mavjudligini belgilaydi.
O'rnatish chizmasi Teshik namunasi, o'lchamlar va o'rnatish interfeyslarini tasdiqlaydi.
lzzbj6-9-10-c1.2-dimensions-03.webp

Nima uchun ushbu oila konfiguratsiya tekshiruvini lozim qiladi

Ushbu mahsulotlar oilasining farqi – aniq belgilangan LZZBJ seriyasidagi bir nechta 10 kV oqim transformatorlari konfiguratsiyalarini qamrab olish qobiliyatida. Biror bir versiyaning universal ravishda eng yaxshi ekanligini da'vo qilish o'rniga, taqdim etilgan ma'lumotlar oqim doirasi, aniqlik kombinatsiyasi, himoya sinfi, ikkinchi darajali chiquvchi quvvat, g'ildiraklar soni va mexanik format bo'yicha muhandislik asosidagi solishtirishni qo'llab-quvvatlaydi. Bu neytral tanlash usuli ayniqsa, panelda o'lchov, himoya, terminal va o'rnatishni bitta qarorga birlashtirish kerak bo'lganda foydali.

LZZBJ(6/9)-10 C(1/2) 10 kV li ustun turidagi mustahkamlangan qo‘yilma rezinadan yasalgan tok transformatori himoya sinfi bilan shuning uchun tanlangan chizmadan va loyiha ma'lumotlar varaqasidan ko'rsatilishi kerak. Manba materiallari MOQ 1, to'lov T/T orqali va to'lov qabul qilgandan keyin 20 kun ichida yetkazib berish muddati ko'rsatilgan; tijorat shartlari yakuniy buyurtma uchun etkazib beruvchi bilan qaytadan tasdiqlanishi kerak. Taklif qilinayotgan konfiguratsiyani chiqarishdan oldin tekshirish uchun to'liq elektr va mexanik talablarga asoslanib batafsil texnik taklif va narx taklifi so'raladi.

lzzbj6-9-10-c1.2-dimensions-01.webp

LZZBJ(6/9)-10 C(1/2) 10 kV ustun shaklidagi kuchaytirilgan qoplamali rezinaviy tok transformatori, himoya sinfi bilan

Nominal birinchi darajali tok 5-3000 A; aniqlik 0.2S/10P10, 0.5S/10P10, 0.2/10P10, 0.5/10P10, 0.2S/10P15; chiqish quvvati 10-30 VA; 1 s issiqlik 0.75-80 kA

So'rov yuborish

Xususiy mahsulotlar

Bepul taklif oling

Bizning vakilimiz tez orada siz bilan bog'lanadi.
Email
Ism
Kompaniya nomi
Message
0/1000